Render substrate · Basroc Pty Ltd

Basroc. Non-combustible, fire-rated, knife-cut.

A mineral wool render panel with reinforcing mesh stitched to both faces. The substrate we specify when the wall needs an FRL, sits inside the boundary setback, or the project has to be non-combustible.

Key facts
  • Panel2200 × 600 mm, about 10 kg each
  • Thickness50, 75 and 100 mm (100 mm special order)
  • CoreMineral wool, fibreglass mesh both faces, no crystalline silica
  • FixingDirect fix to studs, or cavity fix on vertical steel battens
  • FireNot deemed combustible to AS 1530.1; FRL up to 90/90/90 on timber, -/90/90 on steel
  • BushfireBAL-FZ to AS 3959
  • WindN1–N4, non-cyclonic
  • ThermalPanel R1.35 / R1.85 / R2.50; total wall up to R5.54
  • ClassesNCC Class 1–10
  • CertificationCodeMark CM70139, Bureau Veritas
  • Warranty7 years; 10 years with Basroc membrane

What it is

Basroc is a rendered lightweight panel built on a mineral wool core rather than foam. The core is non-combustible, and the mesh stitched through both faces gives the panel the stiffness to handle like a board and the crack resistance to take a two-coat render. It cuts with a serrated knife, so there is no cutting bay, no power tools and no silica dust on site.

It is the only CodeMark-certified mineral wool render panel for framed walls in Australia, which is why it appears on Cladding Safety Victoria's list of replacement materials. For us it is the answer to the walls EPS cannot do.

System build-up

  • Breathable building wrap and Basroc flashing tape to every opening and the base of wall
  • Steel cavity battens on-stud where a drained cavity is specified
  • Basroc panel screwed through 48 mm washers to every stud at 250 mm centres, 3 mm gaps foamed with fire-stop foam
  • Aluminium external angles, starter channel and back-blocking at vertical joints
  • Basroc Panel Render, two coats at 3 mm with 160 g alkali-resistant mesh embedded in the first
  • Basroc primer, trowel-on acrylic texture, optional tinted membrane for the 10-year warranty

Where it fits

Boundary walls inside the 900 mm setback, party walls between townhouses, garage walls to a neighbouring lot, and anything on a bushfire-prone block rated above BAL-29. It is also the substrate that unlocks Class 2 to 9 and Type A and B work for a rendered finish, where the NCC requires the external wall to be non-combustible.

On a multi-lot site we often pair it with an EPS system: Basroc on the fire-rated elevations, EPS on the rest, one render system over both.

Limits to design around

Not for cyclonic regions C and D. Not bracing and not load-bearing. Fixtures must be screwed into framing, not the panel. Keep the finished surface below 80 degrees, so flues, barbecues and hot water units stay clear of the wall. Control joints every 6 to 8 metres and at every floor level. Render within two weeks of fixing, never on wet panel.

Compliance

Certification and evidence.

What the certificate covers, and what we hand over to prove the installation matches it.

CodeMark Certificate of Conformity CM70139 Rev 3 is issued by Bureau Veritas Australia against NCC 2022 and covers Volumes One and Two: structure, weatherproofing, lightweight construction, non-combustible elements, bushfire and energy efficiency. Fire resistance comes from Warringtonfire testing to AS 1530.4 with the FRL conditional on off-stud joints being back-blocked, fire-stop foam at every joint and two 3 mm render coats.

We hand over the current certificate, the fixing schedule for the lot's wind class, the signed installation checklist and the Basroc project certification. The certificate of installation is lodged online with batch numbers and photographs and is the document any later warranty claim depends on.

Installation

How we fix and render it.

Rendered corner detail
Render being applied with a trowel

Frame checked square and plumb with double studs or back-blocking at every vertical panel joint. Wrap, tape, battens if cavity fixed, then panels bottom-up in stretcher bond with the 3 mm joint foamed. Angles glued to every corner and opening, sills cut with a 7 degree fall, butterfly mesh at corners. First render coat with full mesh and 100 mm laps, second coat once cured, prime, texture and membrane.

PPE for cutting is a P1 mask, gloves, eye protection and long sleeves, which is the manufacturer's rule rather than a silica requirement.

Warranty and maintenance

Seven years on the complete system from date of purchase, extended to ten when a tinted Basroc membrane is applied. The warranty requires annual maintenance logged with Basroc: a low-pressure wash, inspection of control joints and sealants, and prompt crack repair. We give the owner the maintenance guide and the first year's log sheet at handover.

Downloads

Manufacturer documents.

Linked to the manufacturer's own hosting so you always get the current revision. Our own guides are on the resources page.

  • Technical and Installation Manual V2
    Direct Fix and Cavity Fix, 50/75/100 mm, March 2026
    Open PDF
  • CodeMark Certificate CM70139 Rev 3
    Bureau Veritas, revalidated March 2026
    Open PDF
  • Basroc Panel Safety Data Sheet
    V2.0, March 2026
    Open PDF
  • Basroc Panel Render TDS
    Coverage and mixing
    Open PDF
  • Material calculator
    Basroc online quantity tool
    Open PDF
Start a package

Send us your plans.

We price the substrate, render and paint as one package and come back with system options that suit the site, the wind class and the programme.

Request a package quote

Phone
+61 408 028 108

Email
hello@bespokecladdingandrender.com.au

Region